Specifications

Best Temperature Measurement Accuracy±2 °C
Detector Resolution320 x 240pixel
Dimensions17 x 12.2 x 27.7cm
Display Resolution640 x 480pixel
Display Size3.7in
Field of View23 x 17°
Focus TypeManual
Height27.7cm
Horizontal Detector Resolution320pixel
Horizontal Display Resolution640pixel
Horizontal Field of View23°
Interchangeable LensYes
Interface TypeUSB
Length17cm
Maximum Temperature Measurement+150 °C
Minimum Focus15 (Thermal Lens) cm, 45 (Visual Lens) cm
Model Number pTiR32
Refresh Rate9Hz
Storage MediaSD Card
Thermal Sensitivity=40mK
Vertical Detector Resolution240pixel
Vertical Display Resolution480pixel
Vertical Field of View17°
Visual CameraYes
Voice RecorderYes
Weight1.05kg
Width12.2cm
Not quite what you were looking for?
Quickly find other suitable products by removing those features above which are not essential and clicking Find.
Find

TRi32/TIR29/TiR27 Building Diagnostic Thermal Imagers

Designed for industrial and commercial environments
-20 °C → +150 °C temperature range, ± 2 °C accuracy
High thermal sensitivity (NETD) identifies very small temperature differences
9Hz image refresh rate
2.0 °C minimum thermal span & dewpoint temperature alarm for building diagnostic applications
Automatic alignment (parallax correction) of visual and infrared images images with Fluke IR-Fusion
Telephoto and wide angle lenses available separately for added versatility and special applications.
One-handed focus capability, emissivity correction, reflected background temperature compensation, and transmission
Engineered and tested to withstand a 2 metre drop
Withstands dust and water – tested to an IP54 rating
Easy to navigate 3 button menu.
Stores IR & visual images plus voice annotations on a 2GB SD card

  TiR32 TiR29 TiR27
Temperature measurement range (not calibrated below -10 °C) -20 °C → +150 °C -20 °C → +150 °C -20 °C → +150 °C
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater ± 2 °C or 2 % (at 25 °C nominal, whichever is greater ± 2 °C or 2 % (at 25 °C nominal, whichever is greater
Detector type 320 x 240 pixels,
Focal Plane Array, uncooled microbolometer
280 x 210 pixels,
Focal Plane Array, uncooled microbolometer
240 x 180 pixels,
Focal Plane Array, uncooled microbolometer
Total pixels 76,800 58,800 43,200
Thermal sensitivity ≤0.04 °C at 30 °C (40 mK) ≤0.045 °C at 30 °C (45 mK) ≤0.045 °C at 30 °C (45 mK)
Focus mechanism Manual, one-handed Smart Focus capability Manual, one-handed Smart Focus capability Manual, one-handed Smart Focus capability
Palettes 8 Standard and 8 Ultra Contrast 8 Standard and 8 Ultra Contrast 8 Standard and 8 Ultra Contrast
IR-Fusion Yes Yes Yes
Storage medium SD Memory Card – 2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations 3000 basic bitmap (.bmp) images, 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader SD Memory Card – 2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations 3000 basic bitmap (.bmp) images, 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader SD Memory Card – 2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations 3000 basic bitmap (.bmp) images, 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader
File formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.mpg and .jpeg) files
Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.mpg and .jpeg) files
Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.mpg and .jpeg) files
Software SmartView® full analysis and reporting software included SmartView® full analysis and reporting software included SmartView® full analysis and reporting software included
Batteries Two lithium ion rechargeable, field replaceable smart battery packs with five segment display to show charge level Two lithium ion rechargeable, field replaceable smart battery packs with five segment display to show charge level Two lithium ion rechargeable, field replaceable smart battery packs with five segment display to show charge level
Visible light camera      
Resolution 2.0 Megapixel 2.0 Megapixel 2.0 Megapixel
Minimum focus distance 46 cm 46 cm 46 cm
Standard infrared lens (supplied)      
Field of view 23° x 17° 23° x 17° 23° x 17°
Minimum focus distance 15 cm 15 cm 15 cm
Optional telephoto infrared lens RS stock no. 682-7558      
Field of view 11.5° x 8.7° 11.5° x 8.7° 11.5° x 8.7°
Spatial resolution (IFOV) 0.63 mRad 0.63 mRad 0.63 mRad
Minimum focus distance 45 cm 45 cm 45 cm
Optional wide-angle infrared lens. RS stock no. 682-7549      
Field of view 46° x 34° 46° x 34° 46° x 34°
Spatial resolution (IFOV) 2.50 mRad 2.50 mRad 2.50 mRad
Minimum focus distance 7.5 cm 7.5 cm 7.5 cm
Image presentation      
Standard palettes Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Level and span Smooth auto-scaling and manual scaling of level and span Smooth auto-scaling and manual scaling of level and span Smooth auto-scaling and manual scaling of level and span
Minimum span 2 °C (manual mode), 3 °C (auto mode) 2 °C (manual mode), 3 °C (auto mode) 2 °C (manual mode), 3 °C (auto mode)
AC operation AC adapter/charger 110//230 V ac, 50/60Hz AC adapter/charger 110//230 V ac, 50/60Hz AC adapter/charger 110//230 V ac, 50/60Hz
Size and Weight (including battery) 277 x 122 x 170 mm; 1.05 kg 277 x 122 x 170 mm; 1.05 kg 277 x 122 x 170 mm; 1.05 kg

Supplied with

Standard infrared lens, ac power supply and battery pack charger (including mains adapters), two lithium ion smart battery packs, SD memory card, multi-format USB memory card reader, SmartView® software, hard carrying case, soft transport bag, adjustable hand strap, printed users manual, interactive training DVD

http://img-europe.electrocomponents.com/images60/E0379448-01.jpg

Thermal cameras