Specifications
| Adapter Type | AC | |
| Best Accuracy | ±1 % | |
| Cable Length Extended | 1.5m | |
| Connector Type | BNC | |
| Maximum AC Current | 240A ac | |
| Maximum Conductor Size | 20mm | |
| Maximum Operating Temperature | +55°C | |
| Minimum Operating Temperature | -10°C | |
| Model Number p | MN09 | |
| Output Type | Current | |
| Safety Category | CAT III 600 V | |
| Safety Category Level | CAT III | |
| Safety Category Voltage | 600V |
Quickly find other suitable products by removing those features above which are not essential and clicking Find.
Find
MN Series 200A a.c. Mini Clamps
Single and dual range mini clamps with nominal current measuring range of 0.5A to 200A ac
40Hz to 10kHz bandwidth
MN09, MN11 & MN21 ac current output 1mA ac / 1A ac for use with multimeters & recorders with a 200mA ac range
MN13, MN39 ac voltage output 10mV ac / 1A ac for use with multimeters & recorders with 200mV ac range. MN39 has a dual 20A/200A range with 0.1A ac minimum measurement
Conforms to: IEC1010-2-032 (safety standard) 600V Cat III
MN89 dc voltage output 100m Vdc / 1Aac for use with multimeters & recorders with mV dc and Vdc inputs, advantageous for multimeters as their mV dc ranges are often more sensitive than their ac current ranges
Ergonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cable
Fitted with a 1.5m flying lead with 4mm shrouded plugs to suit most multimeters
Output voltage limiter prevents high output voltage if clamp output becomes open circuited (MN11 & MN21 only)
| Ref | MN09 | MN11 | MN13 | MN21 | MN39 | MN89 |
| Nominal range (In) | 200Aac | |||||
| Measurement Range (Aac) | 0.5 to 240 | 0.1 to 240 | 0.1 to 24 0.5 to 240 | 0.5 to 240 | ||
| Output type | Aac | Aac Protect | Vac | Aac Protect | Vac | Vdc |
| Output ratio Per 1Aac | 1mAac | 10mVac | 10mVac | 1mAac | 100mVac 10mVac | 100mVdc |
| Accuracy (@In) | 1% | 5% | 1% | 2% | ||
| Impedance of Measure device | 1Ω | >1MΩ | 1Ω | >1MΩ |