Refine by
| (4) | |
| (1) | |
| (4) | |
| (27) | |
| (1) | |
| (7) | |
| (4) | |
| (6) | |
| (1) | |
| (1) | |
| (10) |
| (1) | |
| (3) | |
| (1) | |
| (2) | |
| (2) | |
| (2) | |
| (2) | |
| (2) | |
| (1) | |
| (1) | |
| (2) | |
| (1) | |
| (1) | |
| (1) | |
| (2) | |
| (4) | |
| (2) | |
| (2) | |
| (10) | |
| (1) | |
| (1) | |
| (2) | |
| (4) | |
| (1) | |
| (2) | |
| (2) | |
| (2) | |
| (1) | |
| (1) | |
| (1) | |
| (1) | |
| (1) | |
| (1) |
| (2) | |
| (2) | |
| (1) | |
| (1) | |
| (1) | |
| (4) | |
| (3) | |
| (1) | |
| (1) | |
| (1) | |
| (2) | |
| (2) | |
| (3) | |
| (4) | |
| (8) | |
| (1) | |
| (2) | |
| (1) | |
| (1) | |
| (1) | |
| (1) | |
| (2) | |
| (2) | |
| (3) | |
| (4) | |
| (3) | |
| (2) |
| (2) | |
| (2) | |
| (1) | |
| (18) | |
| (3) | |
| (2) | |
| (5) | |
| (7) | |
| (2) | |
| (1) | |
| (3) | |
| (4) |
| (2) |
| (4) | |
| (1) | |
| (8) | |
| (1) | |
| (2) | |
| (4) | |
| (1) | |
| (2) | |
| (2) | |
| (2) | |
| (4) | |
| (4) | |
| (5) | |
| (6) | |
| (1) | |
| (1) | |
| (1) | |
| (1) | |
| (1) | |
| (1) | |
| (1) | |
| (4) |
| (17) | |
| (10) | |
| (1) |
| (2) | |
| (2) | |
| (1) | |
| (1) | |
| (1) | |
| (8) | |
| (2) | |
| (3) |
| (1) | |
| (1) | |
| (4) | |
| (3) | |
| (2) | |
| (12) | |
| (2) | |
| (2) | |
| (4) | |
| (1) | |
| (2) | |
| (2) | |
| (3) | |
| (1) | |
| (3) | |
| (2) | |
| (8) | |
| (2) | |
| (2) | |
| (1) |
| (3) | |
| (1) |
| (1) | |
| (1) | |
| (2) | |
| (2) | |
| (1) | |
| (1) |
| (2) | |
| (4) |
Loading please wait...
Brand / Part No |
Temperature Range |
Accuracy |
Resolution |
Power |
Emissivity |
Price | |||
|---|---|---|---|---|---|---|---|---|---|
|
Raytek
RSCST25XXEU | -32°C → +535°C | ±1% or ±1°C | 0·2°C | - | Preset at 0.95 |
£164.00Each
|
||
|
Raytek
RSCST25XXEU | -32°C → +535°C | ±1% or ±1°C | 0·2°C | - | Preset at 0.95 |
£254.00Each
|
||
|
SKF
TKTL 30 | - | - | - | - | - |
£235.00Each
|
||
|
Calex
PYROPEN E | -20 → +500°C | ±1% or ±1°C | 1°C | - | Adjustable between 0.3 and 1 |
£202.00Each
|
||
|
Calex
PYROPEN L | -20 → +500°C | ±1% or ±1°C | 1°C | - | Adjustable between 0.3 and 1 |
£217.00Each
|
||
|
Calex
PYROPEN E | -20 → +500°C | ±1% or ±1°C | 1°C | - | Adjustable between 0.3 and 1 |
£112.00Each
|
||
|
Calex
PYROPEN L | -20 → +500°C | ±1% or ±1°C | 1°C | - | Adjustable between 0.3 and 1 |
£127.00Each
|
||
|
Ecom
RSCMTISG | -18 to +260°C | -18 to -1°C: ±3°C; 0 to 99°C: ±2°C; 100 to 260°C: ±2% | - | - | Fixed at 0.95 |
£249.00Each
|
||
|
Ecom
RSCMTISG | -18 to +260°C | -18 to -1°C: ±3°C; 0 to 99°C: ±2°C; 100 to 260°C: ±2% | - | - | Fixed at 0.95 |
£300.00Each
|
||
|
Fluke
FLUKE 561 HVACPRO | -40°C → +550°C | ±1% or ±1°C | 0.1 | - | Variable 0.3 Low, 0.7 Medium, 0.95 High |
£116.00Each
|
||
|
Fluke
FLUKE 561 HVACPRO | -40°C → +550°C | ±1% or ±1°C | 0.1 | - | Variable 0.3 Low, 0.7 Medium, 0.95 High |
£206.00Each
|
||
|
Fluke
FLUKE 566 | -40 °C → 650°C | 1% | 0.1°C | - | - |
£406.00Each
|
||
|
Fluke
FLUKE 566 | -40 °C → 650°C | 1% | 0.1°C | - | - |
£316.00Each
|
||
|
Fluke
FLUKE 568 | -40 °C → 800°C | 1% | 0.1°C | - | - |
£507.00Each
|
||
|
Fluke
FLUKE 568 | -40 °C → 800°C | 1% | 0.1°C | - | - |
£417.00Each
|
||
|
Fluke
FLUKE 572 | -30 → +900°C | ±1% or ±0.75°C | 0.1°C | - | 0.10 to 1 |
£682.00Each
|
||
|
- | - | - | - | - |
£52.14Each
|
|||
|
Fluke
FLUKE 574 | -30 → +900°C | ±1% or ±0.75°C | 0.1°C | - | 0.10 to 1 |
£1,017.00Each
|
||
|
Fluke
FLUKE 572CF | -30 → +900°C | the greater of: ±1% of the reading or ±0.75°C | 0.1°C | - | 0.10 to 1 by 0.01 |
£772.00Each
|
||
|
Fluke
FLUKE 574CF | -30 → +900°C | ±1% or ±0.75°C | 0.1°C | - | 0.10 to 1 |
£1,017.00Each
|